INSTALLATION INSTRUCTIONS FOR 1-3/8" BIFOLD DOORS
R
OUGH OPENING FOR NEW CONSTRUCTION
The construction of the rough opening for single or double bifold doors should be designed so that the opening conforms to our recommended finished opening dimensions. The fin-
ishing of the rough opening can be either a wood frame or drywall because the bifold installation hardware that comes with the bifold can be surface-mounted to either material.
RECOMMENDED FINISHED OPENING DIMENSIONS
This chart allows for a 1/8” (3.2 mm) gap at the top of the bifold and a 1/4” (6.4 mm) space on the sides of the bifold, after it has been installed. The installation hardware is adjustable
so that you achieve these tolerances. It also allows for clearance over any finished floor covering. Your bifold is purchased on the basis of a nominal size which is
slightly larger than the actual size of the bifold.
Standard Finished Opening Standard Finished Opening
D
imensions for 79” Panel Height Dimensions for 77” Panel Height
18” x 80-3/4” 18” x 78-3/4”
24” x 80-3/4” 24” x 78-3/4”
28” x 80-3/4” 28” x 78-3/4”
30” x 80-3/4” 30” x 78-3/4”
32” x 80-3/4” 32” x 78-3/4”
34” x 80-3/4” 34” x 78-3/4”
36” x 80-3/4” 36” x 78-3/4”
NOTE:
T
he above chart reflects standard finished openings only. It does not indicate stock availability.
Not all sizes are available in all markets as a stock item. Some sizes are only available through special order.
E
XISTING FINISHED OPENING
I
f your finished opening is non-standard and you cannot fit your bifold into this opening, you will have
to contact your dealer so that a custom-sized bifold can be ordered from Masonite
®
.
HARDWARE:
M
asonite bifolds are hinged with 1” top track, with top pivot bracket supplied. Hardware packs
c
ontaining all hardware necessary for installation are polybagged complete with instructions.
W
E SUPPLY:
T
his package contains all the necessary hardware components for a complete installation. For multiple door installations, components are included as shown on package
l
abel. TRACK, SNUGGER GUIDE, TOP PIVOTS, BOTTOM PIVOT, JAMB BRACKET, ALIGNERS, SCREWS and DOOR PULL. (HINGES are already installed on doors.)
NOTE:
If your hardware package is different from the above, follow the instructions on the hardware package. Door panels are specified on package chart.
YOU SUPPLY:
Screwdriver, tape measure, hacksaw, wood saw, drill and 3/16” (5 mm.) drill bit.
How to Install your Bifold Doors:
Please read the complete instructions carefully before
you start installation. All instructions apply to any size
of folding door installation. The same instructions also
apply to all types of door panels.
1
Measure exact height and width of finished opening.
Finished Opening
________________
high
________________
wide
2
Cut track
If necessary, cut
track to 3 mm (1/8”)
less than the width of
the finished opening.
Use a fine tooth
hacksaw
.
3
I
nstall track
Ensure that the pivot bracket in the
track is at the side which you prefer your doors to open
toward. Now, fasten the track along the center line of the
header, using screws provided.
4
Tap in pivots
Tap top pivots and
bottom pivot into
place. Several light
taps directly on top
of the pivot should
seat it properly
.
Note: Universal pivots are also sold separately.
5
Install jamb bracket
Place jamb bracket, tight to floor,
so that center hole of bracket is
plumb with hole in the top pivot
bracket (in track). Fasten to side
jamb of opening, using screws
provided. It may be necessary to remove existing
baseboard to ensure flush fit.
6
Install pivot door panel
Install the door by inserting the top pivot into the
pivot bracket in track. Lift the door and seat bottom
pivot into jamb bracket.
7
Install snugger guide
Insert snugger guide into the track. Depress guide pivot
and position under track and release so guide pivot is
securely positioned in track.
8
Adjust door
for height
Lift door and
remove bottom
pivot from jamb
bracket. Rotate
the bottom pivot,
as required, to adjust
to proper height. Rotate
clockwise to raise the door; counter-clockwise to
lower it. Do not attempt to turn pivot while engaged
in the jamb bracket.
9
Adjust door to be plumb
Lift door and slide bottom pivot into desired
position.
Using screwdriver
, loosen screw in top pivot bracket
and slide it until door
is plumb. T
ighten screw in top
pivot bracket.
10
Door pull
Drill hole for door pull
in center of guide door
panel at suitable height.
NOTE: For raised panel
b
ifolds, placement may
vary by profile.
11
Attach aligners
For 4-panel installation only
. Attach aligners to back
of guide door panels, approximately
12” (30cm) from
the floor
. Adjust in or out in slotted holes until doors
“snap” closed. T
ighten screws.
12
Adjustment for 4-panel installation
On 4-panel installation, doors may be “snugged”
independently, if desired. Drive a screw partially into
the track at the center of the opening to act as a stop
for the two snugger guides.
13
Cross-section and trim options
Note: For best per
formance of your bifold doors, the
track should not be painted. If you wish, a silicone
lubricant may be applied for even smoother operation.
TOP VIEW
SIDE VIEW
Use a wood strip to conceal
bifold hardware if desired.
(width x height)
Doors
Aligners
Jamb Bracket
Bottom Pivot
Pull
Top Pivots
Snugger Guide
Track
Top Pivot Bracket
Masonite
®
is a registered trademark of Masonite International Corporation
06-0453dHMD Printed in USA 10/06
D
ouble bifold units can be mounted together for openings
up to 72” wide
1010
Masonite Helpline 1-800-663-Door (3667)
9:00 am - 9:00 pm Monday - Saturday
10:00 am - 4:00 pm Sunday, EST
website : www.masonite.com
Page view 0
1 2

Summary of Contents

Page 1 - Using screwdriver

INSTALLATION INSTRUCTIONS FOR 1-3/8" BIFOLD DOORSROUGH OPENING FOR NEW CONSTRUCTIONThe construction of the rough opening for single or double bif

Page 2 - ORNILLERIA

Masonite es una marca comercial registrada de Masonite International Corporation 06-0453dHMD Impreso en los 10/06INSTRUCCIONES PARA LA INST

Comments to this Manuals

No comments